Skived Copper Finned Heat Sink
A Skived Copper Finned Heat Sink is a thermal management component with fins formed directly from a solid copper base, creating a one-piece structure for heat transfer and dissipation. It is primarily used in power electronics, inverters, telecommunications equipment, industrial power supplies, and server cooling systems.
- Product Introduction
A Skived Copper Finned Heat Sink is a thermal management component with fins formed directly from a solid copper base, creating a one-piece structure for heat transfer and dissipation. It is primarily used in power electronics, inverters, telecommunications equipment, industrial power supplies, and server cooling systems.
Technical Specifications
|
Parameter |
Specification |
|
Product Name |
Skived Copper Finned Heat Sink |
|
Manufacturer |
ZP HEATSINK |
|
Material |
Copper |
|
Fin Structure |
Integral skived fins |
|
Maximum Fin Width |
500 mm |
|
Maximum Fin Height |
100 mm |
|
Minimum Fin Gap |
0.25 mm |
|
Fin Thickness |
0.1–2 mm |
|
Recommended Fin Thickness |
0.305–0.610 mm (0.012–0.024 in) |
|
Base Thickness |
1–30 mm |
|
Maximum Length |
3,000 mm |
|
General Tolerance |
±0.2 mm |
|
Manufacturing Method |
Copper fin skiving |
|
Secondary Operations |
Cutting, deburring and drawing-dependent machining |
|
Customization |
Fin geometry, base dimensions and additional processing |
Copper Skived Fin Construction
Integral Fin Structure
Fins are cut directly from the copper base without soldering, brazing or adhesive bonding.
Continuous Thermal Path
The one-piece structure eliminates bonded fin interfaces and their associated thermal resistance.
High-Density Fin Arrangement
Thin, closely spaced copper fins increase the heat transfer surface area within a compact footprint.
Solid Copper Base
The solid copper base conducts heat from mounted components and supports the fin array.
Copper Fin Inspection
Fin Geometry Inspection
Fin thickness, spacing, pitch, height and count are checked against approved drawings. Results are evaluated against the approved drawing tolerances.
Fin Integrity Inspection
Fins are visually inspected for bending, cracks, burrs, edge damage and misalignment. Acceptance is based on specified defect limits and minimum clearance requirements.
Base and Mounting Inspection
Base thickness, overall dimensions, mounting-hole positions and contact-surface flatness are checked using appropriate dimensional instruments. Surface roughness is measured when specified on the drawing.
Inspection Standards
Dimensional and geometric acceptance follows the approved engineering drawing and agreed tolerances. Inspection methods, sampling frequency and reporting requirements are defined by the applicable quality plan.
Custom Drawing Review
Fin Geometry Review
Fin thickness, spacing, height and base dimensions are assessed together for copper skiving feasibility.
Secondary Machining
Mounting holes, threaded features and base grooves can be evaluated for additional machining where sufficient copper material remains.
Heat Pipe Integration
For designs requiring embedded heat pipes, base channels and the necessary assembly operations can be incorporated into the project.
Prototype Development
Custom samples can be produced for dimensional verification, assembly evaluation and customer-defined thermal testing.
Production and Supply Terms
Prototype Lead Time
ZP's general custom heat sink prototyping period is typically 7–15 days. Copper skived fin sample schedules are determined by the required geometry and processing scope.
Production Lead Time
General custom heat sink production typically takes 25–35 days. Material availability, machining requirements and order quantity determine the schedule for copper skived fin orders.
Packaging
Packaging is selected according to fin geometry and handling requirements, with particular attention to protecting thin copper fins during transport.
International Delivery
ZP supplies overseas industrial customers from Foshan, China. Shipping methods and Incoterms are specified in the quotation.
Technical Documents
Approved Drawings
Production drawings identify the agreed dimensions, critical tolerances and revision level.
Material Certificates
Copper grade, material standard and supporting certificate requirements are defined in the purchase specification.
Inspection Reports
Dimensional inspection records and first-article reports can be included as part of the agreed quality documentation.
Material Compliance
RoHS, REACH and other applicable material compliance documentation is reviewed according to the supplied product and customer requirements.

Frequently Asked Questions
Q: Does a skived copper finned heat sink require forced airflow?
A: Not necessarily. Natural convection may be suitable for lower heat loads, while closely spaced fins often benefit from forced airflow. The cooling method should be evaluated against the heat load, ambient temperature and allowable component temperature.
Q: How does airflow resistance affect cooling performance?
A: Narrow fin channels increase pressure drop, potentially reducing airflow through the heat sink. Fan selection should consider the fan's pressure–flow curve and the system resistance curve rather than free-air airflow ratings alone.
Q: Can the heat sink be installed in different orientations?
A: Orientation affects natural convection because airflow depends on the direction of the fin channels. In forced-air systems, airflow direction and obstructions generally have a greater influence on cooling performance.
Q: Is thermal interface material required between the heat sink and the electronic component?
A: Thermal interface material is commonly used to reduce contact resistance between mating surfaces. Selection should consider thermal resistance, bond-line thickness, mounting pressure, electrical insulation requirements and operating temperature.
Q: How does copper oxidation affect heat sink performance?
A: Normal surface oxidation does not necessarily cause significant cooling degradation. However, oxidation or contamination at the component mounting interface can increase thermal contact resistance.
Q: Can copper skived fin heat sinks be used in humid or corrosive environments?
A: Suitability depends on exposure conditions. Humidity, salt contamination and corrosive chemicals can accelerate copper corrosion. Protective finishes and material compatibility should be evaluated for the operating environment.
Q: Can copper heat sinks cause galvanic corrosion when mounted against other metals?
A: Yes. Galvanic corrosion can occur when dissimilar metals are electrically connected in the presence of an electrolyte. Electrical isolation or suitable protective finishes can reduce the risk.
Q: How does the weight of copper affect equipment integration?
A: Copper is denser than aluminum, increasing assembly weight for comparable volumes. Mounting strength, mechanical support and vibration loads should be considered in weight-sensitive equipment.
Hot Tags: skived copper finned heat sink, China skived copper finned heat sink manufacturers, suppliers, factory